| BOILER |
Boilers can be integrated into a range of systems, from radiant slab to hot water baseboard to ventilation fans blowing across hot water coils. Like furnaces, Annual Fuel Utilization Efficiencies (AFUEs) range from 80% to 87% for oil systems and from 80% to 98% for gas (natural and propane) systems. To attain efficiencies greater than 90%, you must use condensing gas boilers. Additional efficiency options include "low mass" (low water content) boilers, increased boiler insulation, control options to reset boiler water temperature based upon outdoor air temperatures, and variable speed control of the circulating pump operation and/or the ventilation fan operation. In all cases, NEMA PremiumTM motors improve overall system efficiencies.
| DIRECT EXPANSION AC |
Direct expansion evaporator coils are incorporated into forced-air systems that can supply a mix of outdoor air and "return" air. These systems typically use furnaces to provide heating. Efficiency is measured in Energy Efficiency Ratio (EER) or Seasonal Energy Efficiency Ratio (SEER). Baseline systems often have a SEER of 10. High-efficiency units, available with SEERs of 16 and above, typically include higher efficiency compressors (i.e. scroll compressors) and condensing and evaporating fans, and increase the surface area of the condensing unit. Variable speed compressors and fans, as well as NEMA PremiumTM motors, also increase efficiencies.
| CHILLED WATER |
To provide cooling, chilled water loops are installed in a coil and a mixture of outdoor and "return" air is blown across. (This system can also use hot water coils (from boilers) to provide heating.) The primary energy user in a chilled water system is the chiller's compressor bank. Baseline systems are often reciprocating compressors-while scroll, screw, or centrifugal compressors offer higher efficiency options, depending upon the size and application. You can also improve the efficiency of chilled water production by reducing condenser water temperature, raising chilled water temperature, varying chilled water flow and condenser fan speed, and installing water-side economizers on the cooling tower systems. Increased efficiencies can be obtained by using variable speed control on chilled water pumps and ventilation fans, and the use of NEMA PremiumTM fan motors.
| FAN COIL |
Heating and cooling efficiencies are based upon boiler, chilled water, and direct expansion equipment efficiencies. The efficiency of the unit itself can be improved by installing a permanent-split capacitor fan motor (for single-phase power applications) or NEMA PremiumTM motors for higher horsepower and three-phase power applications. Occupancy sensors and/or programmable thermostats can be used to control fan operation.
| CENTRAL STATION AIR HANDLING UNITS |
Heating and cooling efficiencies are based upon either boiler or furnace and chilled water or direct expansion equipment efficiencies. Other efficiency measures include NEMA PremiumTM motors and variable frequency drives for fans, demand-controlled ventilation using carbon dioxide sensors, dual-enthalpy economizers, deck temperature reset controls, heat recovery units-such as enthalpy wheels or air-to-air heat exchangers and optimum start-stop strategies.
| CLASSROOM UNIT VENTILATORS |
Cooling efficiencies are based upon direct expansion air conditioning, but are typically limited to a SEER of 12. Heating efficiencies depend upon electric resistance or boiler efficiencies. Boiler-based units are less expensive to operate than electric resistance units and can use the energy efficiency options identified in that section. Occupancy control can reduce demand, either centrally or within each room. Economizer controls can provide free cooling when outdoor air conditions permit.